With the largest display in class, improved low-level signal measurement accuracy and industry-leading probe performance, the 3 Series MDO sets a new standard for bench oscilloscopes. Whether you’re testing your baseband design for IoT or just for simple EMI sniffing, the 3 Series has a unique true hardware spectrum analyzer built right in with superior RF test performance and guaranteed RF specifications.
| KEY FEATURES |
| 2 and 4 analog channel models |
| 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidth models |
| Bandwidth is upgradable (up to 1 GHz) |
| Up to 5 GS/s sample rate |
| 10 M record length on all channels |
| >280,000 wfm/s maximum waveform capture rate |
| Standard passive voltage probes with 3.9 pF capacitive loading and 250 MHz, 500 MHz or 1 GHz analog bandwidth |
| BENEFITS | |
| Low-level signal measurement accuracy improved by as much as 40% | When you are measuring low level signals, it is critical to have a low instrument noise floor for better measurement accuracy. New front-end used in 3 series MDO can help you improve your noise measurements by as much as 40%. When you are evaluating an oscilloscope, be sure to carefully check the random noise specifications of the oscilloscope. Not all oscilloscopes are created equal, and not all oscilloscope manufacturers test and publish their random noise specifications. |
| APPLICATIONS | |
| Embedded Design and IoT | Discover and solve issues quickly by performing system level debug on mixed signal embedded systems including today's most common serial bus technologies with the 3 Series MDO and support for a broad set of common serial buses. |
| Power Design | Make reliable and repeatable voltage, current, and power measurements using automated power quality, switching loss, harmonics, ripple, modulation, and safe operating area measurements with the widest selection of power probes in an affordable solution. |
| Education | Managing multiple instruments on a bench can be troublesome. The 3 Series MDO combines analog, digital, and RF measurements with a signal source in a single, small (5.9 in., 149 mm deep) instrument. The combination of a small instrument and high level of integration aids in the teaching of various electronics principles as well as in its usage for more sophisticated lab experiments. Full upgradeability enables adding functionality over time as needs change or budgets allow. |
| Manufacturing Test and Troubleshooting | Size and space constraints can play havoc on a manufacturing floor. The 3 Series MDO minimizes rack or bench space by integrating multiple instruments into one small package. Integration reduces cost associated with utilizing multiple different instrument types in manufacturing test or troubleshooting stations. |
| Service Installation and Maintenance | Having the right instruments when and where you need them is critical. The 3 Series MDO combines analog waveforms, digital logic, and spectrum analysis in a lightweight (11.7 lbs, 5.3 kg), portable package - making it the perfect choice where space is limited and flexibility is desired. |
| SPECIFICATIONS | |||||
| Model: MDO32 Overview | |||||
| Analog Channel Bandwidth | 100 MHz | 200 MHz | 350 MHz | 500 MHz | 1 GHz |
| Analog Channels | 2 | 2 | 2 | 2 | 2 |
Rise Time (typical, calculated) (10 mV/div setting with 50 Ω input termination) | 3.5 ns | 2 ns | 1.14 ns | 800 ps | 400 ps |
| Sample Rate (1 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 5 GS/s |
| Sample Rate (2 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 5 GS/s |
| Sample Rate(4 ch) | - | - | - | - | - |
| Record Length (1 ch) | 10 M | 10 M | 10 M | 10 M | 10 M |
| Record Length (2 ch) | 10 M | 10 M | 10 M | 10 M | 10 M |
| Record Length (4 ch) | - | - | - | - | - |
| Digital Channels with 3-MSO Option | 16 | 16 | 16 | 16 | 16 |
| Arbitrary Function Generator Outputs with 3-AFG Option | 1 | 1 | 1 | 1 | 1 |
| Spectrum Analyzer Channels | 1 | 1 | 1 | 1 | 1 |
| Standard Spectrum Analyzer Frequency Range | 9 kHz - 1 GHz | 9 kHz - 1 GHz | 9 kHz - 1 GHz | 9 kHz - 1 GHz | 9 kHz - 1 GHz |
| Optional Spectrum Analyzer Frequency Range with 3-SA3 Option | 9 kHz - 3 GHz | 9 kHz - 3 GHz | 9 kHz - 3 GHz | 9 kHz - 3 GHz | 9 kHz - 3 GHz |
| SPECIFICATIONS | ||||
| Model: MDO34 Overview | ||||
| Analog Channel Bandwidth | 100 MHz | 200 MHz | 350 MHz | 500 MHz |
| Analog Channels | 4 | 4 | 4 | 4 |
Rise Time (typical, calculated) (10 mV/div setting with 50 Ω input termination) | 3.5 ns | 2 ns | 1.14 ns | 800 ps |
| Sample Rate (1 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s |
| Sample Rate (2 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s |
| Sample Rate(4 ch) | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s | 2.5 GS/s |
| Record Length (1 ch) | 10 M | 10 M | 10 M | 10 M |
| Record Length (2 ch) | 10 M | 10 M | 10 M | 10 M |
| Record Length (4 ch) | 10 M | 10 M | 10 M | 10 M |
| Digital Channels with 3-MSO Option | 16 | 16 | 16 | 16 |
| Arbitrary Function Generator Outputs with 3-AFG Option | 1 | 1 | 1 | 1 |
| Spectrum Analyzer Channels | 1 | 1 | 1 | 1 |
| Standard Spectrum Analyzer Frequency Range | 9 kHz - 1 GHz | 9 kHz - 1 GHz | 9 kHz - 1 GHz | 9 kHz - 1 GHz |
| Optional Spectrum Analyzer Frequency Range with 3-SA3 Option | 9 kHz - 3 GHz | 9 kHz - 3 GHz | 9 kHz - 3 GHz | 9 kHz - 3 GHz |
| SPECIFICATIONS | ||||||
| 3 Series MDO Mixed Domain Oscilloscope Overview | ||||||
| Model | Analog Bandwidth | Analog Channels | Digital Channels | Sample Rate | Record Length | Spectrum Analyzer |
| MDO32 | 100 MHz - 1 GHz | 2 | 16 (optional) | Up to 5 GS/s | 10 M | 1 GHz (standard) 3 GHz (optional) |
| MDO34 | 100 MHz - 1 GHz | 4 | 16 (optional) | Up to 5 GS/s | 10 M | 1 GHz (standard) 3 GHz (optional) |
| SPECIFICATIONS | |
| 3 Series MDO Mixed Domain Oscilloscope Bandwidth Options | |
| Bandwidth Option | Description |
| 3-BW-100 | 100 MHz Bandwidth for analog channels, 1 GHz spectrum analyzer standard |
| 3-BW-200 | 200 MHz Bandwidth for analog channels, 1 GHz spectrum analyzer standard |
| 3-BW-350 | 350 MHz Bandwidth for analog channels, 1 GHz spectrum analyzer standard |
| 3-BW-500 | 500 MHz Bandwidth for analog channels, 1 GHz spectrum analyzer standard |
| 3-BW-1000 | 1 GHz Bandwidth for analog channels, 1 GHz spectrum analyzer standard |